Convert gas-filled pore volume into a clearly defined standard gas inventory.
All explanations and solutions are visible in this reading view. Use the interactive models to test your understanding. Reading time varies; the minute labels describe the class plan.
Lecture 03 · 90 minutes
00–02 min · 2 min
How much gas does a reservoir volume represent?
Gas expands when its pressure and temperature change. This lecture connects gas-filled pore volume underground to the volume of the same gas at standard conditions. You will calculate a gas formation volume factor, estimate free gas in place, and explain which assumptions prevent the inventory from becoming a recovery forecast.
Conceptual teaching diagram · not to scale
Study explanation
A storage estimate begins with rock and fluid measurements, then uses gas properties to express the stored amount on a common reference basis. The method is straightforward when definitions and units are consistent. The most serious errors often come from mixing reservoir and standard volumes, using gauge pressure, or treating gross thickness as net thickness. Work through the two separate examples and keep their inputs distinct.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0301 / 26
Learning route
02–04 min · 2 min
A sequence from gas behavior to inventory
Refresh pore volume and absolute units. Introduce the real-gas equation, derive a volume ratio, and use it to define Bg. Then combine area, net thickness, porosity, and water saturation to estimate free gas in place. Finish with sensitivity analysis, a calculation exercise, and a check of what remains unknown.
Study explanation
The target skills are interpreting Bg, converting a reservoir gas volume into standard volume, and using a uniform-layer volumetric model correctly. Every result must identify its reference conditions. You will also practice changing one input while holding the others fixed. That exercise shows mathematical dependence; it does not prove that recoverable production changes by the same percentage in a real reservoir.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0302 / 26
Prerequisite refresher
04–07 min · 3 min
Refresh the pore-volume calculation
For a uniform interval, bulk rock volume is area multiplied by thickness. Porosity selects the pore fraction. In a gas–water system, gas saturation is one minus water saturation. Multiplying these quantities produces gas-filled pore volume at reservoir conditions, provided the porosity and saturation definitions are compatible.
\[V_{pg}=Ah\phi(1-S_w)\]
Conceptual teaching diagram · not to scale
Study explanation
Write the sequence in words before using the full formula: bulk rock → pore volume → gas-filled pores. An area of 1 km² is 1,000,000 m², so a 20 m layer has 20 million m³ of bulk rock. Porosity and saturation are fractions, not percentages entered as whole numbers. The pore-volume calculation contains no gas expansion term and therefore cannot yet supply a standard gas inventory.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0303 / 26
Concept
07–10 min · 3 min
Hold the amount of gas fixed
Imagine the same gas moving from reservoir conditions to standard conditions without changing its composition or amount. Its physical volume can change substantially. The two reported volumes describe the same gas amount at different states. A conversion is therefore needed before comparing reservoir storage with standard-condition production or sales volumes.
Conceptual teaching diagram · not to scale
Study explanation
The distinction is similar to describing the same mass at different densities. A small high-pressure gas volume can expand into a much larger volume at lower pressure. No extra gas is created by the change of reference conditions. In a reservoir inventory, we first estimate the space occupied by the gas underground, then calculate what volume the same amount would occupy at the selected standard state.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0304 / 26
Concept
10–13 min · 3 min
The real-gas equation defines the state
The relation pV = nZRT connects absolute pressure p, physical gas volume V, amount n in moles, temperature T in kelvin, and the gas constant R. The dimensionless compressibility factor Z accounts for departure from ideal-gas behavior. A reservoir gas should not automatically be assigned Z = 1.
\[pV=nZRT\]
Conceptual teaching diagram · not to scale
Study explanation
In a calculation of volume ratio for the same gas amount, n and R cancel, so the equation can be used without computing a mole number. Z depends on pressure, temperature, and composition and is supplied for the examples in this course. Do not confuse Z with a compressibility coefficient: Z is a dimensionless correction in the state equation. Always check the pressure and temperature conventions before substitution.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 03S0505 / 26
Units and reference states
13–16 min · 3 min
Use absolute pressure and absolute temperature
Gas equations use pressure referenced to vacuum and temperature referenced to absolute zero. Gauge pressure must be converted to absolute pressure by adding the appropriate atmospheric pressure. Convert degrees Celsius to kelvin by adding 273.15. In a pressure ratio, both pressures must be expressed in the same units.
Study explanation
A ratio of 20 MPa to 101.325 kPa is invalid if the numerical values are used without conversion. Either express both in pascals or use 20 MPa and 0.101325 MPa. Temperature ratios must use kelvin; using 15°C directly in a denominator would be physically incorrect. These checks are especially important because an otherwise correct algebraic formula can still produce an apparently plausible but wrong answer.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0306 / 26
Concept
16–19 min · 3 min
Define the course standard conditions
The course standard state is 101.325 kPa absolute and 288.15 K, equal to 15°C. Take the standard-condition Z factor as one for exercises. Other publications may use a different standard temperature or pressure. Convert their reported gas volumes before comparing them with results on this course basis.
Conceptual teaching diagram · not to scale
Study explanation
The word standard does not uniquely determine the same conditions in every source. A reported quantity must specify the chosen reference pressure and temperature. In this course, standard m³ is a label for gas volume at the stated standard state. Reservoir m³ labels the volume occupied underground. Keeping these labels beside every Bg, inventory, rate, and cumulative volume protects the meaning of the calculations.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0307 / 26
Concept
19–22 min · 3 min
B g is a reservoir-to-standard volume ratio
The gas formation volume factor Bg is reservoir volume divided by standard volume for the same gas amount and composition. Its label is reservoir m³ per standard m³. A small value means the gas occupies a small volume underground compared with its volume at the standard reference state.
\[B_g=\frac{V_{\mathrm{res}}}{V_{\mathrm{sc}}}\]
Conceptual teaching diagram · not to scale
Study explanation
For example, Bg=0.005 reservoir m³/standard m³ means one standard cubic metre corresponds to 0.005 m³ at the specified reservoir state. Conversely, one reservoir cubic metre represents 1/0.005=200 standard m³. The labels indicate different reference states even though both are physical volume units. Always ask which direction a conversion is needed before deciding whether to multiply or divide.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 03S0508 / 26
Concept
22–25 min · 3 min
Derive the volume-factor expression
Apply the real-gas equation once at reservoir conditions and once at standard conditions. Divide the two volume expressions for the same n and composition. The gas amount and gas constant cancel. The resulting ratio contains reservoir Z, temperature, and pressure together with their standard-condition counterparts.
At the reservoir state, Vres=nZRT/p. At the standard state, Vsc=nZscRTsc/psc. Their ratio therefore gives ZT psc divided by ZscTscp. This derivation explains each term and avoids memorizing a field-unit coefficient whose reference conditions may differ. Pressure units cancel only if matched, and both temperatures must be in kelvin.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0309 / 26
Concept
25–28 min · 3 min
Read each term before substituting
Here p and T refer to reservoir pressure and temperature, Z is the reservoir compressibility factor, and the subscript sc means standard conditions. Use the initial reservoir values for an initial-gas-in-place estimate. If pressure changes during production, Bg can also change, so the initial value should be labeled.
Conceptual teaching diagram · not to scale
Study explanation
A state property must be associated with a stated state. The gas formation volume factor in a particular example is not a universal property of methane and not a fixed property of the rock. It depends on the fluid and its pressure and temperature. In the simple volumetric inventory, Bg converts the initial gas-filled reservoir volume. Modeling the later production process requires additional relationships that are outside this single initial estimate.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0310 / 26
Worked example A
28–32 min · 4 min
Worked example A: calculate B g
Use reservoir pressure 20 MPa absolute, temperature 350 K, and Z = 0.90. At standard conditions use psc = 0.101325 MPa, Tsc = 288.15 K, and Zsc = 1. Calculate Bg and interpret the result in reservoir m³ per standard m³.
The pressures are deliberately both expressed in MPa so their ratio is consistent. Substitute 0.90×350×0.101325 in the numerator and 1×288.15×20 in the denominator. The result is approximately 0.0055383, or 0.00554 reservoir m³/standard m³. This is a volume ratio for this particular reservoir state. It will not be reused in the separate volumetric example, which supplies its own Bg.
Worked solution
Bg = 31.917375/5763 = 0.0055383 reservoir m³/standard m³. Thus 1 standard m³ corresponds to about 0.00554 reservoir m³ at this specified state. The reciprocal is the standard gas volume represented by one reservoir m³.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0311 / 26
Concept
32–35 min · 3 min
Check the direction of the conversion
If Bg is reservoir volume divided by standard volume, then standard volume equals reservoir volume divided by Bg. At Bg = 0.005, a gas-filled reservoir volume of 1,000 m³ represents 200,000 standard m³. The large numerical increase reflects expansion to the lower-pressure reference state.
\[V_{\mathrm{sc}}=\frac{V_{\mathrm{res}}}{B_g}\]
Conceptual teaching diagram · not to scale
Study explanation
Use the definition as a unit cancellation check: reservoir m³ divided by reservoir m³ per standard m³ leaves standard m³. Multiplying instead would give the wrong conversion direction for an inventory starting from reservoir pore volume. A quick physical check also helps: ordinary reservoir gas is compressed relative to the standard state, so the reference volume for the same amount is generally larger in these examples.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0312 / 26
Concept
35–38 min · 3 min
From net rock volume to free gas
Free gas occupies pore space as a gas phase. For a uniform gas–water interval, its initial standard volume is area A times net thickness h times porosity φ times gas saturation, divided by initial Bg. This expression estimates stored free gas; adsorbed gas is a separate inventory.
\[G_{\mathrm{free}}=\frac{Ah\phi(1-S_w)}{B_g}\]
Conceptual teaching diagram · not to scale
Study explanation
Area is in m², net thickness in m, and porosity and saturation are compatible fractions. The numerator is reservoir gas-filled pore volume, not bulk rock volume or standard gas volume. The conversion by Bg completes the inventory calculation. This model assumes no oil or hydrate in the modeled pores and representative uniform properties. A more complicated reservoir needs a correspondingly appropriate geological and storage description.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0313 / 26
Concept
38–41 min · 3 min
Net thickness avoids counting nonreservoir rock
Net gas-bearing thickness is the thickness meeting the chosen reservoir criteria. Gross interval thickness can include nonreservoir layers. If a problem supplies gross thickness, apply an explicit net-to-gross fraction before using the volumetric equation. Do not apply that correction again when h is already stated as net thickness.
Conceptual teaching diagram · not to scale
Study explanation
Suppose a 30 m gross interval contains 20 m meeting the selected gas-bearing criteria. The net-to-gross fraction is 20/30, and using gross thickness multiplied by that fraction gives the same net volume as using 20 m directly. The criteria must be stated because a net interval depends on the interpretation. Double-correcting an already net thickness underestimates the modeled storage; ignoring a necessary correction overestimates it.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0314 / 26
Concept
41–44 min · 3 min
Layered rock can be calculated in parts
If representative properties differ between layers, calculate the gas volume of each layer using its own compatible thickness, porosity, saturation, and Bg, then add the standard gas inventories. A single average value can be useful only when its averaging method represents the physical volume being modeled.
Conceptual teaching diagram · not to scale
Study explanation
Arithmetic averaging of unrelated log values is not automatically equivalent to summing gas volumes. A thick layer contributes more rock volume than a thin one, and correlations between porosity and saturation can matter. At this level, dividing the reservoir into simple layers makes the logic visible. Keep the same standard reference conditions for every layer before summation, and avoid including the same rock volume twice.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0315 / 26
Worked example B
44–50 min · 6 min
Worked example B: a separate uniform interval
For this separate fictional example, use area 1 km², net thickness 20 m, porosity 0.08, water saturation 0.25, and a supplied Bg of 0.005 reservoir m³/standard m³. Calculate initial free gas. Do not replace the supplied Bg with the value from example A.
Conceptual teaching diagram · not to scale
Study explanation
Convert 1 km² to 1,000,000 m². The bulk volume is 20 million m³; pore volume is 1.6 million m³; gas-filled pore volume is 1.2 million reservoir m³. Dividing by 0.005 gives 240 million standard m³. Writing these intermediate volumes is a strong check because each step has a distinct physical meaning. The result is an inventory estimate for a uniform model, not a schedule of production.
Worked solution
Bulk volume = 1,000,000 × 20 = 20,000,000 m³.
Pore volume = 20,000,000 × 0.08 = 1,600,000 m³.
Gas saturation = 0.75; gas-filled pores = 1,200,000 reservoir m³.
Gfree = 1,200,000/0.005 = 240,000,000 standard m³.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0316 / 26
Concept
50–53 min · 3 min
What the free-gas answer excludes
The free-gas calculation does not automatically include gas adsorbed on surfaces, gas dissolved in liquids, or gas bound in hydrate. It also does not specify how much of the gas can reach the well. Identify the modeled storage form and assumptions before deciding which additional inventories or production models are needed.
Conceptual teaching diagram · not to scale
Study explanation
In shale and coal, adsorption can contribute an important separate amount. In hydrate-bearing sediment, gas within the solid hydrate phase requires a different inventory. Adding storage components must be done on compatible bases so the same gas is not counted twice. Even a complete initial inventory remains different from technical recovery and reserves. The next lecture develops a simple equilibrium adsorption model and links storage to transport.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0317 / 26
Concept
53–56 min · 3 min
Audit the input and output labels
Before accepting a result, check area conversion, net thickness, fractional porosity, gas–water saturation, and initial Bg. State standard conditions beside the answer. Ask whether measurement definitions match. Finally, describe whether the result is free gas in place, total gas in place, a recoverable scenario, or actual produced gas.
Conceptual teaching diagram · not to scale
Study explanation
These checks are more useful than reporting many decimal places. A very precise answer using an incompatible saturation basis is still incorrect. Volumetric uncertainty can come from mapped area, thickness, heterogeneous properties, and fluid-state measurements. An honest result therefore states assumptions and may report a range. The worked examples use exact teaching inputs to make the method clear; they do not imply field inventories are known that precisely.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0318 / 26
Explore · 8 minutes
56–64 min · 8 min
Explore the sensitivity of free gas
Use the volumetrics explorer to change porosity, water saturation, or Bg one at a time. Predict the response before changing a control. Explain why doubling area doubles modeled gas but doubling Bg halves the standard gas estimate when the other inputs are held fixed.
Study explanation
The formula makes these proportionalities explicit: free gas is proportional to area, thickness, porosity, and gas saturation, and inversely proportional to Bg. The explorer isolates mathematical changes. Geological inputs may be correlated in reality, and changing a state property such as Bg may be associated with other changes. Treat the exercise as a sensitivity study rather than evidence that a reservoir can be improved by adjusting a slider.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0319 / 26
Concept
64–67 min · 3 min
A relative change is not percentage points
If porosity increases by 20% relative to 0.06, the new porosity is 0.06 × 1.20 = 0.072, or 7.2%. The increase is 1.2 percentage points. With other volumetric inputs fixed, free gas rises by 20%. This arithmetic does not establish an equal increase in recoverable production.
Conceptual teaching diagram · not to scale
Study explanation
Relative changes compare a difference with the starting value. Percentage-point changes compare two reported percentages directly. Confusing the two gives very different reservoir estimates. Recovery also depends on connected flow, completion effectiveness, pressure evolution, operating limits, and economics. Porosity may be correlated with some of these factors, but the volumetric equation alone does not quantify the relationship. State exactly what was held fixed in a sensitivity result.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0320 / 26
Practice W03.1
67–73 min · 6 min
W03.1: calculate the standard gas inventory
A fictional interval has area 0.8 km², net thickness 15 m, porosity 0.06, water saturation 0.30, and Bg = 0.004 reservoir m³/standard m³. Calculate initial free gas in place. Show the area conversion, gas-filled pore volume, final conversion, and the reference basis of the answer.
Conceptual teaching diagram · not to scale
Study explanation
The area is 800,000 m² and bulk volume is 12 million m³. Multiplying by 0.06 yields 720,000 m³ of pores. Gas occupies 70% of those pores, so the gas-filled pore volume is 504,000 reservoir m³. Dividing by 0.004 gives 126 million standard m³. Check that each intermediate quantity has the correct meaning rather than entering every input into a calculator in one unexplained step.
In an otherwise unchanged volumetric calculation, porosity increases by 20% relative to its original value. How does estimated free gas change? Explain why this does not establish a 20% increase in recoverable gas. State the model relationship first, then identify the missing production-related evidence.
Conceptual teaching diagram · not to scale
Study explanation
Because porosity appears as a multiplier, the modeled free-gas estimate changes in the same proportion when everything else is fixed. Recoverable gas is a different quantity. More pore space may be isolated, supplied through restrictive throats, or outside effective well drainage. Completion and operating constraints can also dominate. The correct answer therefore contains both the numerical sensitivity and a physically specific limitation.
Worked solution
Estimated free gas increases by 20% because Gfree is proportional to φ under the stated assumptions. Recoverable gas need not increase by 20%: connectivity, permeability, pressure depletion, completion effectiveness, abandonment conditions, and economics are not determined by porosity alone.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0322 / 26
Error diagnosis
76–79 min · 3 min
Find the error in a short calculation
A student enters area as 0.8, thickness as 15, porosity as 6, and water saturation as 30, while Bg is in reservoir m³/standard m³. Identify the errors before calculating. Then explain why adding a standard-volume label to a calculator output cannot repair incompatible input units.
Study explanation
The area must be converted from km² to m², and the percentage values must become fractions. Water saturation should be 0.30, not 30, so the gas fraction is 0.70 rather than a negative number. The units and interpretation of Bg must also match the intended conversion. A unit audit is not merely formatting: it ensures that every multiplication represents the physical operation the equation was derived to perform.
Worked solution
Use A = 800,000 m², φ = 0.06, Sw = 0.30, and gas saturation 0.70. The thickness is already in metres. Dividing the gas-filled reservoir volume by Bg then gives standard volume. Recalculate from corrected inputs; relabeling an incorrect result is insufficient.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0323 / 26
Self-check
79–84 min · 5 min
Check which direction B g must act
A gas-filled pore volume is 10,000 reservoir m³ and Bg is 0.005 reservoir m³/standard m³. Which standard gas volume represents the same amount? Use the definition to cancel the reference-state labels and explain why the chosen numerical direction makes sense for compressed reservoir gas.
What is the corresponding standard gas volume?
Study explanation
Starting from reservoir volume, divide by Bg. The result is 10,000/0.005=2,000,000 standard m³. Multiplication would move in the wrong direction for the stated starting quantity. The much larger standard volume is consistent with expansion from a compressed reservoir state in this example. This simple check is useful before any large volumetric calculation because a reversed factor can dominate every other source of error.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0324 / 26
Concept
84–87 min · 3 min
An inventory is a starting point for development
Free gas in place estimates gas initially present within a modeled volume. Delivery to a well requires connected flow, and recovery requires a production process with stopping conditions. Commercial reserves require a qualifying project. Keep those steps distinct when reporting a large inventory or comparing two appraisal scenarios.
Conceptual teaching diagram · not to scale
Study explanation
The volumetric method helps quantify what might be present, but it does not establish how quickly gas can leave the rock or how much can be produced economically. It is possible to have a large inventory and a poor project. An engineer therefore carries the storage estimate forward into flow, completion, environmental, and economic assessment. Later lectures will show how a production forecast must also be checked against its recoverable-volume assumptions.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0325 / 26
Review and exit check
87–90 min · 3 min
Review: show the physical chain
Explain why pressure and temperature affect reported gas volume. Define Bg and derive its conversion direction. Reproduce the uniform free-gas equation and name its assumptions. Finish by explaining how you would handle gross thickness, variable layers, and a separate adsorbed-gas inventory before calling a result total gas in place.
Conceptual teaching diagram · not to scale
Study explanation
A complete answer connects rock volume to pore space, fluid occupancy, and a reference gas state. It also recognizes the limits of each step. Use the equation reference when needed, but explain what every term does. In Lecture 4, the adsorption model adds an inventory expressed per unit rock mass and introduces the further distinction between gas that could be released at equilibrium and gas delivered to a well.
UNCONVENTIONAL GAS RESERVOIR / LECTURE 0326 / 26
COMPLETE CHAPTER TEXT
Lecture 03: chapter notes
The original student knowledge-base chapter is reproduced below as a continuous reference, alongside the expanded explanations above.
Learning targets
Explain why gas volumes change with pressure and temperature.
Use \(B_g\) consistently.
Estimate free gas in place without calling it reserves.
Core knowledge
Gas expands as pressure decreases, so a reservoir gas volume and a standard gas volume are different representations of the same amount of gas. The real-gas relation is:
\[
pV=nZRT
\]
Here \(n\) is amount of gas in moles, \(R\) is the gas constant, and \(Z\) accounts for departure from ideal-gas behavior. Do not assume \(Z=1\) at all reservoir conditions.
For unchanged gas composition and the same gas amount:
Use absolute temperatures and absolute pressures; reservoir and standard pressures must use the same units. Penn State: Volumetric factors gives the underlying volume relationship.
For a uniform gas–water interval:
\[
G_{\mathrm{free}}=\frac{Ah\phi(1-S_w)}{B_g}
\]
\(A\) is area in m² and \(h\) is net gas-bearing thickness in m. If thickness is gross, first account for net-to-gross. The expression assumes representative, compatible porosity and saturation, no oil or hydrate in the modeled pores, and known initial \(B_g\). Adsorbed gas is separate. For variable layers, calculate each layer and sum them.
Worked example
First, for \(p=20\) MPa, \(T=350\) K, \(Z=0.90\), and the course standard conditions:
This is estimated free gas initially present, not the amount necessarily recoverable or commercial.
Practice
W03.1: Calculate free gas in place for \(A=0.8\) km², \(h=15\) m, \(\phi=0.06\), \(S_w=0.30\), and \(B_g=0.004\) reservoir m³/standard m³.
W03.2: In an otherwise unchanged volumetric calculation, porosity increases by 20% relative to its original value. How does estimated free gas change? Why does this not establish a 20% increase in recoverable gas?
Takeaway: State the volume basis, then separate gas present from gas recoverable.